{"product_id":"lipiview-ii-ocular-surface-interferometer","title":"LipiView® II Ocular Surface Interferometer","description":"\u003cdiv data-salesforce-tracking-mode=\"pageLoad\" data-salesforce-tracking-type=\"Product Page Views\" data-salesforce-element-id=\"22821\" data-salesforce-element-type=\"product_page\"\u003e\n\u003cdiv id=\"js-right-content\"\u003e\n\u003cdiv role=\"tablist\" aria-multiselectable=\"true\" id=\"accordion\"\u003e\n\u003cdiv id=\"product_information\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eLeading innovation in lipid layer thickness measurement and meibomian gland imaging.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #6f5091;\"\u003e\u003cstrong\u003eBenefits:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time visualization of the lipid layer to evaluate the dynamic response of lipids to blinking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatented noise canceling technology to measure sub-micron thickness of the lipid layer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVideo and analysis of blink dynamics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-definition imaging with Dynamic Meibomian Imaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoom lights must be dimmed during testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"223\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearscience_lipiviewpatient_380x283.jpg\" width=\"300\"\u003e\u003c\/p\u003e\n\u003cp\u003eLipiView® II Ocular Surface Interferometer with Dynamic Meibomian Imaging™ (DMI) measures lipid layer thickness (LLT) with nanometer accuracy, captures blink dynamics, and images meibomian gland structure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"223\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearscience_lipiviewllt_380x283.jpg\" width=\"300\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe LipiView® II Interferometer features patented technology that provides a sophisticated assessment of factors that contribute to dry eye. Compelling visuals and video captures provide a unique opportunity to educate patients about their personal ocular health.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDynamic Meibomian Imaging\u003c\/p\u003e\n\u003cp\u003eMEIBOMIAN GLANDS IN HIGH DEFINITION\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"223\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearscience_dmidynamic_380x283.jpg\" width=\"300\"\u003e\u003c\/p\u003e\n\u003cp\u003eDynamic Illumination\u003c\/p\u003e\n\u003cp\u003eSurface lighting originates from multiple light sources to minimize reflection.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"223\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearscience_dmiadaptive_380x283_1.jpg\" width=\"300\"\u003e\u003c\/p\u003e\n\u003cp\u003eAdaptive Transillumination\u003c\/p\u003e\n\u003cp\u003eChanges to the light intensity across the surface of the illuminator compensate for the lid thickness variations between patients.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"223\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearscience_dmidual_380x283.jpg\" width=\"300\"\u003e\u003c\/p\u003e\n\u003cp\u003eDual-Mode DMI\u003c\/p\u003e\n\u003cp\u003eA combination of Dynamic Illumination and Adaptive Transillumination offers an enhanced view of meibomian gland structure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLipiView® II Reporting\u003c\/p\u003e\n\u003cp\u003eREAL-TIME VISUALIZATION\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" height=\"321\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/Tear%20Science\/Lipiview\/11015954jjv_tearsciencelipiviewreporting_560x321.jpg\" width=\"560\"\u003e\u003c\/p\u003e\n\u003cp\u003eLipid Layer Thickness (LLT)\u003c\/p\u003e\n\u003cp\u003ePresents lipid layer thickness measurements in an easy to understand color-coded map.\u003c\/p\u003e\n\u003cp\u003eDynamic Meibomian Gland Imaging\u003c\/p\u003e\n\u003cp\u003eUtilizes advanced illumination technology to capture high-definition images.\u003c\/p\u003e\n\u003cp\u003eBlink Dynamics\u003c\/p\u003e\n\u003cp\u003eAnalyzes blink patterns and detects partial blinks. A graphical representation shows fluctuations in lipid layer thickness measurements between each blink.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eVisualize and Analyze Blinks\u003c\/p\u003e\n\u003cp\u003eAnalyze Blink Patterns\u003c\/p\u003e\n\u003cp\u003eComputerized analysis of blink patterns objectively quantifies the number of complete and partial blinks. Results are displayed in a frame-by-frame graphical representation that shows fluctuations in lipid thickness measurements between each blink. A video capture allows clinicians and patients to review blinking habits during consultation.\u003c\/p\u003e\n\u003cp height=\"322px\" width=\"433px\"\u003e\u003ciframe height=\"322px\" src=\"https:\/\/www.youtube.com\/embed\/JfWoB8seW1I?enablejsapi=1\u0026amp;origin=https%3A%2F%2Fwww.jnjvisionpro.com\" width=\"433px\" data-gtm-yt-inspected-13101269_76=\"true\" id=\"978939913\" data-gtm-yt-inspected-8223130_494=\"true\" allow=\"autoplay; encrypted-media\" allowfullscreen=\"\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eNormal vs Partial Blink\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eVisualize Blink Response\u003c\/p\u003e\n\u003cp\u003eHigh-resolution video depicts how well ocular lipids disperse in response to a blink through variations in light patterns reflected off the tear film called an interferogram. The system enhances the interference pattern and displays a profile corresponding to an interferometry color scale which has been validated to a known standard for lipid layer thickness measurements with a precision of 1 nm and an accuracy of ±10 nm.\u003c\/p\u003e\n\u003cp height=\"322px\" width=\"433px\"\u003e\u003ciframe height=\"322px\" src=\"https:\/\/www.youtube.com\/embed\/nZfpUiNCbtE?enablejsapi=1\u0026amp;origin=https%3A%2F%2Fwww.jnjvisionpro.com\" width=\"433px\" data-gtm-yt-inspected-13101269_76=\"true\" id=\"871260418\" data-gtm-yt-inspected-8223130_494=\"true\" allow=\"autoplay; encrypted-media\" allowfullscreen=\"\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eLipid Imaging Mode\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"benefits\"\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch3\u003eLipiView® II Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time visualization of the lipid layer to evaluate the dynamic response of lipids to blinking\u003c\/li\u003e\n\u003cli\u003ePatented noise canceling technology to measure sub-micron thickness of the lipid layer\u003c\/li\u003e\n\u003cli\u003eVideo and analysis of blink dynamics\u003c\/li\u003e\n\u003cli\u003eHigh-definition imaging with Dynamic Meibomian Imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeature Comparison\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"Feature comparison chart of LipiView II and LipiScan\" height=\"296\" src=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/content\/en-US\/vision-care-resources\/TearScience\/tearscience_integration_chart_1.png\" width=\"580\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.jnjvisionpro.com\/products\/lipiscan%E2%84%A2-dynamic-meibomian-imager\"\u003eLearn more about LipiScan®\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.jnjvisionpro.com\/sites\/us\/files\/public\/Products\/lipiview_ii_fact_sheet.pdf\" target=\"_blank\"\u003eDownload the LipiView® II Fact Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"specification\"\u003e\n\u003ch3\u003eIndications \u0026amp; Safety Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch3\u003eSUMMARY OF IMPORTANT SAFETY INFORMATION\u003c\/h3\u003e\n\u003cp\u003eRx Only\u003c\/p\u003e\n\u003cp\u003eFOR THE LIPIVIEW® II OCULAR SURFCE INTERFEROMETER\u003c\/p\u003e\n\u003cp\u003eINDICATIONS FOR USE\u003c\/p\u003e\n\u003cp\u003eThe LipiView® II Ocular Surface Interferometer is an ophthalmic imaging device that is intended for use by a physician in adult patients to capture, archive, manipulate and store digital images of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpecular (interferometric) observations of the tear film. Using these images, LipiView® II measures the absolute thickness of the tear film lipid layer.\u003c\/li\u003e\n\u003cli\u003eMeibomian glands under near-infrared (NIR) illumination.\u003c\/li\u003e\n\u003cli\u003eThe ocular surface and eyelids under white illumination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCONTRAINDICATIONS\u003c\/p\u003e\n\u003cp\u003eContraindications are conditions in which the device should not be used because the risk of use clearly outweighs any benefit. No contraindications have been identified for LipiView® II.\u003c\/p\u003e\n\u003cp\u003ePRECAUTIONS\u003c\/p\u003e\n\u003cp\u003eThe following patient conditions may affect the interferometry assessment of a patient’s tear film using LipiView® II:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse of ophthalmic drops such as artificial tear lubricants, ointments, and medications. Advise patients not not instill oil-based ophthalmic drops (e.g., Soothe®, Restasis®, Systane Balance®) for at least 12 hours prior to device use and not to instill ointments for at least 24 hours prior to device use. Wait at least four (4) hours after the instillation of all other ophthalmic drops prior to device use.\u003c\/li\u003e\n\u003cli\u003eSoft or rigid contact lens wear. Advise patients to remove contact lenses at least four hours prior to device use.\u003c\/li\u003e\n\u003cli\u003eUse of oil-based facial cosmetics around the eye.\u003c\/li\u003e\n\u003cli\u003eEye rubbing.\u003c\/li\u003e\n\u003cli\u003eRecent swimming in a chlorinated pool. Advise pateints to not to swim for at least 12 hours prior to device use.\u003c\/li\u003e\n\u003cli\u003eAny ocular surface condition that affects the stability of the tear film. These conditions include disease, dystrophy, trauma, scarring, surgery, or abnormality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePOTENTIAL ADVERSE EFFECTS\u003c\/p\u003e\n\u003cp\u003eThere are no known or anticipated adverse effects associated with use of this device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Johnson and Johnson","offers":[{"title":"Default Title","offer_id":32331333959716,"sku":"DER195","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0232\/2232\/1188\/products\/prod-lipiview-cir-a-2_bc9290bf-9a2a-4f21-b23f-713048ed26bf.png?v=1601318319","url":"https:\/\/wholesale.dryeyerescue.com\/products\/lipiview-ii-ocular-surface-interferometer","provider":"Dryeye Rescue Pro","version":"1.0","type":"link"}