In-Office Procedures · Dry Eye Diagnostics

IDRA All-in-one dry eye diagnostic platform.

IDRA is a diagnostic instrument for individual tear film analysis, enabling a rapid and detailed structural assessment of tear composition. It evaluates all tear film layers, including lipid layer thickness and meibomian glands, and is designed to help identify the type of dry eye disease and support personalized treatment recommendations.

IDRA dry eye platform
15 secAutomatic acquisitions in as little as
5 MPImage resolution
10Ocular surface exams in one suite
3DMeibomian gland imaging

How it works

Complete tear film assessment, automated

IDRA uses automatic acquisitions and analysis to assess the lipid, aqueous and mucin layers of the tear film along with the meibomian glands. The results help identify the type of dry eye disease, and the assessment can be delegated to staff.

Identify the dry eye type

Evaluates all tear film layers and the meibomian glands to perform a complete dry eye assessment and help identify the type of dry eye disease.

Fast, automatic acquisitions

Automatic acquisitions are captured in as little as 15 seconds.

Delegable workflow

Dry eye assessment can be easily delegated to staff.

Documented results for patients

Patients receive documented results and treatment options, and 3D meibography gives a clear image to share with them.

Treatment suggestion algorithm

A suggestion algorithm shares a possible treatment approach for each patient, drawing on a database the physician fills with the drugs, supplements and treatments available in the practice.

Automated exams for every tear film layer

IDRA runs on the Instrument Control Platform (ICP), software that performs and analyzes ocular surface tests.

  • Automatic interferometry and NIBUT
  • 3D meibography
  • Blepharitis and dandruff screening
  • Automatic interferometry

    Analyses lipid layer thickness to understand meibomian gland function, and can support follow-up after meibomian gland treatment by detecting an increase in secretion.

  • Automatic NIBUT

    A single video gives automatic NIBUT, an average of more than one value, a graph of tear film stability over time and a tear topography map of break-up.

  • Automatic tear meniscus

    Analyses tear meniscus thickness automatically as a non-invasive measure related to aqueous tear production.

  • 3D meibography

    3D meibomian gland imaging shows the structure of the eyelids and helps confirm abnormal glands compared with a healthy subject.

The exam

The exam workflow

An IDRA assessment is quick, painless and non-invasive, and can be delegated to trained staff.

Patient positioned at the IDRA dry eye platform

Non-invasive capture

Ocular surface and tear film exams are captured non-invasively using infrared and visible light imaging.

Seconds per acquisition

Automatic acquisitions are captured in as little as 15 seconds, and interferometry returns meibomian gland function data in a few seconds.

Results and treatment plan

Patient and data management software allows instant image review, and the suggestion algorithm proposes a possible treatment approach for each patient.

Specifications

Technical specifications
Image resolution 5 MP
Acquisition mode Auto, manual; multi shot, video
Light sources Infrared LED; blue, red and white LED
Sensor Sensitive to infrared (NIR)
Cones Main cone, Placido cone
Exams Interferometry, tear meniscus, NIBUT, 3D meibography, blepharitis and cylindrical dandruff, bulbar redness, white-to-white, pupil diameter, anterior segment imaging, blink quality
Mini PC CPU Intel Core i7-12700, 12 core, 2.10/4.90 GHz
Mini PC RAM 16 GB DDR4 (3200 MHz)
Mini PC GPU Intel UHD 770 4K, 2× DisplayPort, 1× HDMI
Connectivity 2.5 Gb LAN, Wi-Fi 6, Bluetooth 5.2
USB 4× USB 3.2, 2× USB Type-C, 2× USB 2.0
Operating system Windows 11 Pro
Accessories Smart Base, ophthalmic table

Common questions about IDRA

What does IDRA measure?

Lipid layer thickness by interferometry, tear meniscus, NIBUT, 3D meibography, blepharitis and cylindrical dandruff, bulbar redness, white-to-white, pupil diameter, anterior segment imaging and blink quality.

How long does an IDRA acquisition take?

Automatic acquisitions are captured in as little as 15 seconds.

Can staff perform the assessment?

Yes. The dry eye assessment is designed to be easily delegated.

Does IDRA suggest treatments?

Yes. A suggestion algorithm shares a possible treatment approach for each patient, based on a database the physician fills with the drugs, supplements and treatments available in the practice.

Who distributes IDRA in the US?

Reichert Technologies distributes IDRA in the United States under an exclusive partnership with SBM Sistemi.

Comprehensive dry eye assessment in a fraction of the time

IDRA brings automated tear film, meibomian gland and ocular surface analysis together on one platform for your practice.

IDRA is a trademark of SBM Sistemi (distributed in the US by Reichert Technologies). Review the full manufacturer instructions for use, including all warnings, precautions and contraindications, before use. Individual results vary.