Automatic NIKBUT
Non-invasive tear film break-up time is measured automatically within seconds, without fluorescein, using infrared illumination that avoids glare.
In-Office Procedures · Dry Eye Diagnostics
The OCULUS Keratograph 5M is an advanced corneal topographer with a built-in real keratometer and a color camera optimized for external imaging. It supports dry eye workups with non-invasive tear film break-up time, tear meniscus height, lipid layer, meibomian gland and bulbar redness assessments.
How it works
The Keratograph 5M captures tear film, lid and ocular surface measurements without fluorescein, using infrared and white light imaging. Pre-calibrated workflows let technicians capture measurements, and automated analysis feeds a single report for diagnosis, patient education and follow-up.
Non-invasive tear film break-up time is measured automatically within seconds, without fluorescein, using infrared illumination that avoids glare.
Meibo-Scan images the meibomian glands of the upper and lower lids, and Meibo Analytics automatically analyses gland structure and quantifies gland loss.
Tear meniscus height is measured non-invasively, and the lipid layer is evaluated from its interference pattern.
R-Scan classifies bulbar and limbal redness objectively.
The Crystal TEAR Report combines diagnostic images, videos and patient-reported symptoms into one summary for documentation, patient education and monitoring treatment at follow-up.
Placido topography, a real keratometer and multi-wavelength illumination support both dry eye workups and contact lens fitting.
22 Placido rings generate 22,000 real measured data points on the anterior cornea, with Fourier and Zernike analysis.
Measures real anterior surface K values rather than simulated Ks.
White and 880 nm infrared Placido illumination, 465 nm blue light for fluorescein imaging and 840 nm infrared for meibography.
TF-Scan tear film analysis, Meibo Analytics, R-Scan, OxiMap oxygen transmissibility maps, pupillometry and a contact lens fitting database.
The exam
A Keratograph 5M dry eye workup is non-invasive and can be delegated to trained staff.
NIKBUT, tear meniscus height, lipid layer, meibography and redness are captured without fluorescein or contact with the eye.
A four-procedure screening option suits routine patient screening, and NIKBUT is measured automatically within seconds. Tests are performed from least to most invasive.
Results feed the Crystal TEAR Report, and side-by-side comparisons support follow-up visits and monitoring of treatment.
| Accuracy | ±0.1 D |
|---|---|
| Reproducibility | ±0.1 D |
| Number of Placido rings | 22 |
| Measuring points | 22,000 |
| Working distance | 78–100 mm |
| Camera | Digital CCD camera |
| Light sources | Placido: white diodes and infrared diodes (880 nm); imaging: blue diodes (465 nm); meibography: infrared (840 nm); tear film dynamics: white diodes; pupillometry: infrared (880 nm) |
| Dimensions (W × D × H) | 275 × 320–400 × 480–510 mm |
| Weight, measuring head | 3.2 kg |
| Weight, with xy base | 6.1 kg |
| Max. power consumption | 18 W |
| Voltage / frequency | 100–240 V AC, 50/60 Hz |
| Data export | NIKBUT, R-Scan and keratometric data to CSV |
No. There are differences between non-invasive keratograph break-up time and fluorescein tear film break-up time.
Measurement is difficult when there is severe corneal epithelial damage, and results typically show very short values.
No. The software detects distortions, although advanced keratoconus or severe irregular astigmatism makes measurement challenging.
Meibo Analytics automatically analyses gland structure and quantifies gland loss, and the JENVIS Grading Scales allow direct comparison against grading references.
It provides examinations that support the diagnosis.
No. Placido topography measures the anterior cornea only.
Yes. NIKBUT, R-Scan and keratometric data can be exported to CSV files.
The Keratograph 5M combines corneal topography with non-invasive tear film, meibomian gland and redness assessment in one device.
Keratograph 5M is a trademark of OCULUS. Review the full manufacturer instructions for use, including all warnings, precautions and contraindications, before use. Individual results vary.